Three Victron DC power distribution modules connected to the Wymondham home battery system

Pylontech Battery Storage Upgrade in Wymondham

Ets. yearly savings

£810

Installation size

14.4kW

Est. yearly Co2 savings

810kg

Est. yearly energy

4,500kWh

Google Reviews
Google Reviews
4.9

Electric11 expanded an existing domestic energy-storage system in Wymondham by installing three Pylontech US5000C batteries. The upgrade added 14.4 kWh of storage and increased the property’s total battery capacity from 42 kWh to 56.4 kWh.

The additional batteries were integrated into an existing grid-connected, three-phase system powered by three Victron Quattro 48/8000/110 inverter-chargers.

Project Overview

  • Location: Wymondham, Norfolk
  • Property type: Domestic
  • System type: Grid-connected three-phase energy-storage system
  • Existing batteries: 12 Pylontech US3000C units
  • New batteries: 3 Pylontech US5000C units
  • Additional storage: 14.4 kWh
  • Total storage after upgrade: 56.4 kWh
  • Increase in capacity: 34.3%
  • Inverter setup: 3 Victron Quattro 48/8000/110 inverter-chargers
  • Combined inverter capacity: Approximately 24 kVA

The Existing Home Energy System

The property already had a substantial three-phase battery-storage system consisting of 12 Pylontech US3000C batteries. Together, these provided 42 kWh of storage capacity.

Three Victron Quattro 48/8000/110 inverter-chargers managed the system, providing approximately 24 kVA of combined inverter capacity across the three-phase installation.

Rather than replacing the existing equipment, the project focused on expanding the available storage while retaining the established Victron and Pylontech setup.

Adding 14.4 kWh of Pylontech Battery Storage

Electric11 supplied and fitted three Pylontech US5000C batteries, each providing 4.8 kWh of nominal storage capacity. Together, the new units added 14.4 kWh to the system.

The battery count increased from 12 to 15 units, while total storage rose from 42 kWh to 56.4 kWh. This represented a 34.3% increase in available battery capacity.

The expanded system gives the property more capacity to store electricity for later use while continuing to operate through the existing three-phase Victron inverter arrangement.

Integrating the Batteries With the Existing Victron System

The new Pylontech batteries were incorporated into the property’s existing grid-connected energy-storage system. Retaining the three Victron Quattro inverter-chargers allowed the customer to expand storage without replacing the core inverter equipment.

This type of upgrade requires the existing batteries, inverter configuration, communication setup, and available installation space to be assessed before additional units are fitted. Battery compatibility and system limits must also be confirmed as part of the project planning.

Battery Capacity After the Upgrade

Following the installation, the system provided:

  • 56.4 kWh of total battery storage
  • 14.4 kWh of newly added capacity
  • 34.3% more storage than the original system
  • 15 Pylontech batteries in total
  • Approximately 24 kVA of inverter capacity

The completed upgrade increased the amount of energy the property could retain without requiring a complete replacement of the existing storage system.

Considering a Battery Upgrade in Wymondham?

Existing battery-storage systems can sometimes be expanded when the installed inverter, battery models, system configuration, and available space support additional capacity.

Electric11 can assess your current equipment and recommend whether expansion, replacement, or a different configuration would be appropriate. Learn more about our home battery storage services in Wymondham or contact our team to arrange an assessment.

Request a Battery Storage Assessment
Victron SmartSolar MPPT charge controller and isolation switch installed with the Wymondham battery system.
Three Victron Quattro inverter-chargers connected to a Pylontech battery storage system in Wymondham.
Three Victron DC power distribution modules connected to the Wymondham home battery system
Expanded bank of 15 Pylontech batteries providing 56.4 kWh of home energy storage in Wymondham.

The Electric11 solar
installation process

We understand that solar installation can seem disruptive. That’s why we focus on providing efficient, thorough service with minimal inconvenience. Here’s why you don’t need to worry.

Comprehensive Assessment

Our experienced electricians will conduct a detailed inspection of your home’s electrical system to determine the scope of the solar wiring system.

Detailed Transparent and Competitive Quote

We’ll provide a transparent and cost-effective quote outlining all aspects of the job, with no hidden surprises or add-ons.

Customised Planning

We’ll discuss the optimal placement of the battery storage unit to meet your needs and preferences. A property solar array and battery storage is an excellent opportunity to improve the energy storage and usage to match your tastes.

Our qualified electricians will do the wiring work with minimal disruption to your daily life. We ensure your property is cleaned daily.

Thorough Testing and Certification

After rewiring the electrical equipment, we conduct rigorous electrical tests to ensure compliance with the latest safety standards (BS 7671). You’ll receive an Electrical Installation Certificate verifying the safety and compliance of your new electrical system.

More Case studies

View all case studies

Solar PV Inspection and EICR Review in Long Stratton

Electric11 assessed an existing solar PV system and associated electrical records in Long Stratton, highlighting documentation conflicts and items requiring follow-up.

Ets. yearly savings

£0

Installation size

0kW

Est. yearly Co2 savings

0kg

Est. yearly energy

0kWh

Pump Supply Investigation and Trenching in East Runton

Electric11 completed trenching for a pump electrical supply at Pip’s Bothy in Lower Common, East Runton. The project records and follow-up photographs also document the existing pump, cable route and intake equipment so that the next electrical work could be scoped safely.

Ets. yearly savings

£0

Installation size

1kW

Est. yearly Co2 savings

0kg

Est. yearly energy

0kWh

16-Panel Solar, Battery Storage and EV Charger Installation in Wymondham

Electric11 installed a 16-panel solar PV system, 11.52 kWh Fox ESS battery and Zappi EV charger at a Wymondham bungalow, creating one integrated home-energy system.

Ets. yearly savings

£1,360

Installation size

7.36kW

Est. yearly Co2 savings

1,170kg

Est. yearly energy

6,620kWh

Fox ESS Solar Battery Storage Installation in California, near Great Yarmouth

Electric11 added a 7 kW Fox ESS hybrid inverter and 11.52 kWh heated battery to an existing solar-powered home in California, near Great Yarmouth. The retrofit also included cable alterations, protection, commissioning and BS 7671 certification.

Ets. yearly savings

£605

Installation size

7kW

Est. yearly Co2 savings

627kg

Est. yearly energy

3,027kWh

Commercial PAT Testing in Wicklewood, Near Wymondham

Electric11 completed PAT testing for a Wicklewood ice cream business, checking mobile catering equipment, freezers, leads and everyday appliances. Several clear pass readings were recorded, while a failed result showed the value of testing equipment before continued commercial use.

Ets. yearly savings

£0

Installation size

0kW

Est. yearly Co2 savings

0kg

Est. yearly energy

0kWh